Friday, April 15, 2016

A Few Simple Principles Guide You To The Best Seal Flush Plan - EastMachinery

Are you Tired to watching your money spiral down the drain from mechanical seal repair or replacement? A few simple principles can guide you to the best seal flush plan for your installed mechanical seal, allowing the seal to operate in an environment that generates optimal seal life yet minimizes costs from water usage and product dilution. Today, we'll identify 4 flush piping plans for single mechanical seals and how they work. In future articles, we'll dive into double mechanical seals and packing, so stay tuned!

1. No Flush

Can only be used if the pumped fluid is clean, does not exceed the temperature limits of the seal, is compatible with the seal components, and is in no danger of vaporizing or solidifying when exposed to the additional friction heat generated by the seal. If this plan is used, a tapered or self-venting seal chamber is highly recommended.

2. Bypass Flush

This method is used when the pumped fluid is clean, does not exceed the temperature limits of the seal, and is compatible with the seal components. It's not recommended if the pumped fluid contains solids that could adversely affect the seal or if the temperature of the pumped fluid exceeds the maximum temperature for the seal.

Normally, this method consists of piping run from the pump discharge to the flush connection on the seal gland, providing flow from the pump, past the seal, and back into the pump through the seal chamber throat. It can also be piped from the flush connection on the seal gland back to the pump suction, which would result in the flow going the opposite direction and can have the added benefit of lowering the operating pressure at the seal. If warranted, accessories such as a heat exchanger or pressure reducing orifice can be installed in the piping.

A bypass flush provides circulation flow past the seal faces to carry away seal generated heat, so the seal operating temperature will stabilize at the temperature of the pumped fluid. This method is simple, reliable, and inexpensive. It does not result in product dilution and is the preferred seal flush method unless there is a specific reason not to use it.

--- To be continued